Adlink ACL-8112 Series Manuale Utente Pagina 34

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 92
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 33
26 Signal Connections
AIHn
AILn
n = 0, ..., 8
Groun
Signal
Sourc
To A/D Converter
VG1 VG2
Vcm = VG1 - VG2
GND
+
-
Figure 3.5 Ground source and differential input
A differential mode must be used when the signal source is differential. A
differential source means the ends of the signal are not grounded. To avoid
dangerously high voltages between the local ground of the signal and the
ground of the PC system, a shorted ground path must be connected.
Figure 3.6 shows the connection for a differential source.
AIHn
AILn
n = 0, ..., 8
Differentia
Signal
Sourc
To A/D Converter
VG1 VG2
Vcm = VG1 - VG2
GND
+
-
Figure 3.6 Differential source and differential input
Vedere la pagina 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 91 92

Commenti su questo manuale